Storage tanks with a capacity of 2,350 l and 5,500 l

Project information

Dimensions: 2000 l tank Ø 1,300mm, total height 4,155mm; dimensions: 5000 l tank Ø 1,750mm, total height 4,155mm. At the top: circumferential reinforcement profile and planar, screwed-on cover with 1/3 flap cover part and inserted safety grating. At the bottom: Conical bottom with incline of ∠28°

Materials:

  1. Tank completely made of 1.4301/1.4541
  2. Screws made of A2

Surface treatment:

  1. Inner and outer surfaces pickled and passivated

Operating data:

  1. The tank has been designed for pressureless operation at 50 °C max.
  2. Acceptance by manufacturer

Info:

References

Satisfied customers are the best proof for good work. We are very proud of a large number of existing customers that choose us time and again due to our high quality. Here you will find a selection of references from different industrial sectors.

Subterraneous collecting tanks for 10,000 l

Project information

Dimensions: Ø 1,610mm, total length 5,350mm. Laterally with torospherical heads according to DIN 28011. Equipped on all sides with a double jacket for monitoring the tightness with an overpressure system. (The corresponding leakage indicator was part of the scope of supply.) With tank vehicle connection DN 80 with immersion tube and coupling VK 80 in the dome DN 800 × 1100mm height.

Materials:

  1. Parts in contact with the product made of 1.4571
  2. Remainder made of 1.4301/1.4541

Surface treatment:

  1. Inner and outer surfaces pickled and passivated

Operating data:

  1. The tanks have been designed for pressureless operation; however, they have been made subject to a tightness test with 2 bars water pressure in the interior and 0.6 bar in the double jacket.
  2. Acceptance according to WHG (Water Resources Act)